Table of Contents
Importância de testar os níveis de oxigênio dissolvido na água
O oxigênio dissolvido é um componente crítico da qualidade da água que impacta diretamente a saúde dos ecossistemas aquáticos. É essencial para a sobrevivência dos organismos aquáticos, pois dependem do oxigênio para respirar. O monitoramento dos níveis de oxigênio dissolvido na água é crucial para avaliar a saúde geral de um corpo de água e identificar fontes potenciais de poluição.
Existem vários métodos disponíveis para testar o oxigênio dissolvido na água, cada um com suas próprias vantagens e limitações. Um método comum é o método Winkler, que envolve a adição de reagentes a uma amostra de água para precipitar o oxigênio dissolvido na forma de dióxido de manganês. A quantidade de oxigênio presente é então determinada titulando a amostra com uma solução padronizada de iodo.
Outro método amplamente utilizado é o método do eletrodo de membrana, que utiliza um sensor que mede a concentração de oxigênio na água detectando mudanças na corrente elétrica. Este método é rápido, preciso e adequado tanto para ambientes de campo quanto de laboratório.
Independentemente do método utilizado, é importante seguir os procedimentos adequados para garantir resultados precisos. Antes do teste, é essencial calibrar todos os equipamentos e garantir que as amostras sejam coletadas adequadamente para evitar contaminação. É também crucial registar todos os dados relevantes, incluindo temperatura e pH, uma vez que estes factores podem influenciar a solubilidade do oxigénio na água.
A monitorização regular dos níveis de oxigénio dissolvido é essencial para detectar alterações na qualidade da água ao longo do tempo. Baixos níveis de oxigênio dissolvido podem indicar poluição de fontes como escoamento agrícola, descarga de esgoto ou efluentes industriais. Por outro lado, níveis elevados de oxigénio dissolvido podem ser um sinal de crescimento excessivo de algas, o que pode levar ao esgotamento do oxigénio e prejudicar a vida aquática.
Ao testar os níveis de oxigénio dissolvido na água, os cientistas ambientais e os gestores da qualidade da água podem avaliar a impacto das atividades humanas nos ecossistemas aquáticos e tomar medidas adequadas para proteger e restaurar a qualidade da água. O monitoramento do oxigênio dissolvido é particularmente importante em áreas com altos níveis de poluição por nutrientes, pois o excesso de nutrientes pode levar à proliferação de algas e ao esgotamento do oxigênio.
Modelo | Analisador automático on-line de cloro livre série CLA-7000 (DPD) |
Canal de entrada | Canal único/Canal duplo |
Faixa de medição | Cloro livre\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\:(0,0\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\~2.0)mg/L ou (0,5\\\\\\\\\\\\\\\\\\\\ \\\\\\\\\\\~10.0)mg/L, calculado como Cl2; pH:(0-14); Temperatura(0-100)\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\℃ |
Precisão | Cloro livre:\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ 110 por cento ou \\\\\\\\\\ \\\\\\\\\\\\\\\\\\\\\ 10,1/0,25 mg/L; pH:\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\±0,1pH\\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\;Temperatura\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\ \:\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\u005\\\\\\\\\\\\ \\\\\\\\\\\\\\\\\\℃ |
Período de medição | \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\≤2,5min |
Intervalo de amostragem | O intervalo (1\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\~999) min pode ser definido arbitrariamente |
Ciclo de manutenção | Recomendado uma vez por mês (ver capítulo de manutenção) |
Requisitos ambientais | Uma sala ventilada e seca sem vibração forte;Temperatura ambiente recomendada\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\:(15\\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\~28)\\\\\\\\\\\\\\\\\\ \\\\\\\\\\\\\℃\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\;Umidade relativa\ \\\\\\\\\\\\\\\\\\\\\\\\\\\\\:\\\\\\\\\\\\\\\\\\ \\\\\\\\\\\\\≤85 por cento \\\\\\\\\\\\\\\\\\\\\\\\\\\\\\(Não condensação\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\) |
Fluxo de amostra de água | (200-400) mL/min |
Pressão de entrada | (0,1-0,3) barra |
Temperatura da água de entrada | (0-40)\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\℃ |
Fonte de alimentação | AC (100-240)V\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\; 50/60Hz |
Poder | 120W |
Conexão de energia | O cabo de alimentação de 3 núcleos com ficha está ligado à tomada com fio terra |
Saída de dados | RS232/RS485/(4\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\\~20)mA |
Tamanho | A*L*D:(800*400*200)mm |
Além da sua importância para os ecossistemas aquáticos, testar o oxigénio dissolvido na água também é crucial para garantir a segurança da água potável. Baixos níveis de oxigênio dissolvido podem promover o crescimento de bactérias e patógenos nocivos, representando um risco para a saúde pública. Ao monitorar os níveis de oxigênio dissolvido nas fontes de água potável, as estações de tratamento de água podem tomar medidas proativas para manter a qualidade da água e proteger os consumidores.
Concluindo, testar o oxigênio dissolvido na água é uma ferramenta vital para avaliar a qualidade da água, identificar fontes de poluição e proteger os ecossistemas aquáticos. Ao utilizar métodos fiáveis e seguir procedimentos adequados, os cientistas ambientais e os gestores da qualidade da água podem recolher dados precisos para informar a tomada de decisões e salvaguardar a saúde dos nossos recursos hídricos. A monitorização regular dos níveis de oxigénio dissolvido é essencial para detectar alterações na qualidade da água e tomar medidas oportunas para enfrentar ameaças potenciais. Em última análise, garantir níveis adequados de oxigénio dissolvido na água é essencial para manter a saúde e a sustentabilidade dos ecossistemas aquáticos para as gerações futuras.